Cypress Integration Solutions’ OSDP data splitter allows sharing of an OSDP reader with two OSDP panels. The splitter (ODM-2010) directs the reader’s credential data to both OSDP systems. PD port one, connected to the primary controller, has full control over the reader and sends I/O messages such as LED/buzzer commands. PD port two connects to the secondary controller and sends credential data only; OSDP I/O commands receive NAK replies. Along with the ODM-2010, a custom OSDP data splitter is available, to share an OSDP reader with two panels, to send credential data to one panel or the other based on a custom credential configuration. Also available are versions which allowing sharing OSDP reader data with one OSDP panel and one Wiegand panel.

Cypress Integration Solutions | www.cypressIntegration.com